
BRANICK 1500 Nitrogen Generator, Triple Membrane Technology
Branick 1500 Triple Membrane Nitrogen Generator - 21.3 SCFM Commercial Grade System
The Branick Model 1500 delivers 21.3 SCFM of nitrogen output at 160 PSI through triple-membrane PRISM technology designed for high-volume commercial tire shops. Built with American steel construction in Fargo, North Dakota, this stationary system uses a 1.9:1 air-to-nitrogen ratio while simultaneously functioning as an air dryer with -70°F dewpoint output.
Key Features & Benefits
Highest Membrane Output Capacity
The Branick 1500 produces 21.3 SCFM of nitrogen at 160 PSI through triple-membrane PRISM separation technology, exceeding standard membrane-based competitors while maintaining consistent purity throughout operational lifespan. This industrial-grade output supports multiple service bays without pressure degradation during peak demand periods.
Traditional nitrogen generators struggle to maintain flow rates when multiple technicians operate pneumatic tools simultaneously. The Model 1500 addresses this industry-wide challenge by providing sustained high-volume output that enables concurrent tire service operations across busy commercial facilities.
This enables safer and more efficient fleet maintenance by eliminating nitrogen supply bottlenecks during heavy service periods. Shop managers can schedule multiple bay operations without compromising nitrogen availability or extending service times.
Integrated Air Drying Function
PRISM membrane technology simultaneously removes moisture while generating nitrogen, producing -70°F dewpoint output without requiring separate air drying equipment. This dual-function design eliminates the need for costly PSA system components while delivering bone-dry nitrogen for optimal tire performance.
Moisture contamination in nitrogen systems causes tire pressure fluctuations and accelerated rim corrosion in commercial vehicle operations. Standard systems require additional air dryers and maintenance schedules, increasing operational complexity and parts inventory costs.
This eliminates separate air treatment equipment and reduces maintenance overhead while ensuring consistent tire pressure in temperature-sensitive applications like refrigerated transport and precision equipment hauling.
Superior Efficiency Ratio
The 1.9:1 air-to-nitrogen conversion ratio minimizes compressor wear and energy consumption compared to less efficient systems requiring higher air input volumes for equivalent nitrogen output. This efficiency rating reduces operational costs while extending connected equipment lifespan through optimized duty cycles.
Inefficient nitrogen generators force compressors to run longer cycles and higher pressures, increasing energy consumption and accelerating component wear. Fleet operators face elevated utility costs and frequent compressor maintenance when using systems with poor conversion ratios.
This reduces monthly energy expenses and extends compressor service intervals by minimizing unnecessary runtime. Facilities can achieve target nitrogen production with smaller, less expensive air compressors while maintaining operational reliability.
Automatic Compressor Protection
Built-in shut-off system activates at optimal pressure ranges to prevent unnecessary compressor operation, featuring automatic pressure switch and solenoid valve controls that monitor system demand and cycle equipment accordingly. This intelligent control reduces energy costs and extends connected equipment lifespan through precise operational management.
Manual nitrogen systems waste energy through continuous compressor operation regardless of actual demand, leading to premature equipment failure and excessive utility costs. Technicians often forget to shut down systems during break periods, resulting in unnecessary wear cycles.
This improves operational efficiency by eliminating manual oversight requirements and reducing wasted compressor runtime. Shop owners benefit from lower utility bills and extended equipment warranties through automated system management.
Product Demonstration
Applications & Use Cases
- High-Volume Commercial Tire Shops: Multi-bay service centers requiring continuous nitrogen supply for simultaneous tire mounting and balancing operations across multiple service positions
- Off-The-Road (OTR) Heavy Equipment Service: Mining, construction, and agricultural equipment tire service requiring high-volume nitrogen for large-diameter tires and earth-moving machinery
- Commercial Truck and Bus Fleet Maintenance: Transportation companies maintaining large vehicle fleets with consistent nitrogen inflation requirements for optimal fuel efficiency and tire longevity
- Heavy-Duty Tire Service Centers: Specialized facilities handling industrial equipment, logging machinery, and specialized transport vehicles requiring professional-grade nitrogen systems
Technical Specifications
| Specification | Value |
|---|---|
| Nitrogen Output | 21.3 SCFM at 160 PSI, 75°F |
| Air Input Required | 41.4 SCFM at 160 PSI, 75°F |
| Air Input Range | 100-175 PSI operational |
| Nitrogen Purity | 95% to 99.9% adjustable |
| Air to Nitrogen Ratio | 1.9:1 efficiency rating |
| Dewpoint | -70°F nitrogen moisture content |
| Specification | Value |
|---|---|
| Overall Dimensions | 19" W × 19" D × 72" H |
| Operating Temperature | 40°F to 150°F range |
| Inlet/Outlet Ports | 3/8" NPT female connections |
| Power Requirements | Standard 110/120V electrical |
| Construction | American steel, Fargo ND |
| Part Number | 00-0063 |
Installation Requirements
Foundation & Mounting
- Installation Surface: Level floor installation surface required for proper tower alignment
- Base Plate: Anchor point provisions available through integrated base plate mounting holes
- Floor Anchoring: Optional securing through base plate mounting system (anchors not included)
Power & Air Supply
- Electrical: Standard 110/120V electrical outlet access required
- Air Supply: Compressed air supply line connection (minimum 30 ft recommended distance)
- Compressor Requirements: Air compressor capable of 41.4 SCFM at 160 PSI sustained output
Environmental Requirements
- Ventilation: Adequate ventilation required for operational performance
- Operating Temperature: 40°F to 150°F operational range
- Clearances: Sufficient access space for filter maintenance and operational monitoring
Shipping & Delivery
Freight Coverage
Shipping: LTL freight shipping to commercial addresses (lower 48 states). Alaska, Hawaii, and territories excluded from standard shipping coverage.
Delivery Requirements: Residential delivery and liftgate service incur additional charges.
Delivery Requirements
Unloading Equipment: Ships on pallet requiring dock or forklift for safe unloading. Standard residential delivery limitations apply.
Receiving: Inspect all packages before signing bill of lading. Note any visible damage on BOL before driver departs.
Warranty Coverage
Multi-Tier Coverage Program
60 Months - Nitrogen Membranes: Complete membrane coverage with proper filter maintenance requirements
12 Months - Parts Coverage: Comprehensive parts replacement from delivery date
12 Months - Labor Coverage: Installation and service labor coverage from delivery date
Service Support
Technical Support: Monday-Friday 7:30am-4:30pm CST availability for installation and operational assistance
Warranty Requirements: Proper filter maintenance required to maintain membrane warranty coverage
Ready to Upgrade Your Shop?
Get expert guidance on the right nitrogen generator for your facility. Our team can help with product selection, installation planning, and technical specifications. Call to confirm included accessories and installation requirements for your facility.
Frequently Asked Questions
What is the nitrogen output capacity of the Branick 1500?
The Branick 1500 produces 21.3 SCFM of nitrogen at 160 PSI and 75°F, with adjustable purity from 95% to 99.9%. The system uses a 1.9:1 air-to-nitrogen ratio for efficient operation, requiring 41.4 SCFM of compressed air input. This high-volume output supports multiple service bays simultaneously in commercial tire shops and OTR facilities, maintaining consistent pressure throughout peak operational periods.
What components are included with the Branick 1500 system?
The system includes triple membrane tower assembly with PRISM separators, dual pre-filter system with maintenance indicators, automatic shut-off valve and pressure controls, air inlet and nitrogen outlet pressure gauges, nitrogen purity test port, electrical controls, and installation base plate with anchor provisions. The complete package provides everything needed for nitrogen generation except the external air compressor and electrical connection. All components are manufactured with American steel construction in Fargo, North Dakota.
What are the installation requirements for the Branick 1500?
Installation requires a level floor surface, standard 110/120V electrical outlet, compressed air supply line connection, and air compressor capable of 41.4 SCFM at 160 PSI sustained output. Minimum 30 ft recommended distance from air compressor to nitrogen generator. The unit measures 19" wide by 19" deep by 72" high and includes base plate anchor provisions for optional floor mounting. Adequate ventilation is required for proper operation within the 40°F to 150°F temperature range.
What applications is the Branick 1500 designed for?
The Model 1500 is designed for high-volume commercial tire shops, off-the-road heavy equipment service, commercial truck and bus fleet maintenance, and heavy-duty tire service centers requiring continuous nitrogen supply for large tire volumes and multiple service bay operations. The 21.3 SCFM output capacity handles mining equipment, construction machinery, agricultural equipment, logging machinery, and specialized transport vehicles. This system excels in facilities that service multiple large-diameter tires simultaneously or maintain extensive commercial vehicle fleets.
What safety features does the Branick 1500 include?
The system includes automatic shut-off system to prevent over-pressurization, integrated pressure relief valve protection, American-made steel construction meeting commercial durability standards, and automatic pressure controls that cycle equipment based on demand to prevent unnecessary compressor operation. The automatic shut-off valve activates at optimal pressure ranges to protect connected air compressors from excessive wear. All electrical components comply with commercial safety standards and include standard power cord with proper grounding for safe 110/120V operation in industrial environments.
What is the warranty coverage for the Branick 1500?
The system includes 60-month nitrogen membrane coverage with proper filter maintenance, 12-month parts coverage from delivery date, and 12-month labor coverage from delivery date. Technical support is available Monday-Friday 7:30am-4:30pm CST. The 60-month membrane warranty significantly exceeds typical 12-24 month industry coverage, providing long-term protection for the most expensive system components. Warranty requires proper filter maintenance to maintain membrane coverage, and parts coverage includes all system components except normal wear items like filters.
How is the Branick 1500 shipped and what are delivery requirements?
The unit ships via LTL freight to commercial addresses in the lower 48 states on a pallet requiring dock or forklift for unloading. Residential delivery and liftgate service incur additional charges. Alaska, Hawaii, and territories are excluded from standard shipping. The system ships as a complete assembled unit on a pallet base, requiring proper freight receiving capabilities at the delivery location. Customers must inspect all packages before signing the bill of lading and note any visible damage before the driver departs.
What makes the Branick 1500 more efficient than other nitrogen generators?
The 1.9:1 air-to-nitrogen conversion ratio minimizes compressor wear and energy consumption compared to less efficient systems. PRISM membrane technology simultaneously removes moisture while generating nitrogen, eliminating the need for separate air drying equipment and producing -70°F dewpoint output. This dual-function design reduces operational costs and maintenance requirements by consolidating air treatment and nitrogen generation into a single system. The efficient conversion ratio means smaller air compressors can achieve target nitrogen production while maintaining operational reliability and reducing monthly energy expenses.
About the Brand
